Sign In | Join Free | My qualitytoyschina.com |
|
Brand Name : VENTECH
Model Number : Horizontal Concealed Fan Coil Units
Certification : CE
Place of Origin : CHINA
MOQ : 1 unit
Price : 1000USD-5000USD/unit
Payment Terms : L/C, T/T, Western Union
Supply Ability : 50 Containers Per Month
Delivery Time : 30-60days
Packaging Details : standard pallet packing
Product name : Horizontal Concealed Fan Coil Units
Working pressure : CE
Working temperature : different Working pressure
Retun air : DB 27℃/WB 19.5℃
Model : Rooftop package unit
Lead time : 30 days after receiving prepayment
Warranty : 2 years after date of shipment
Trademark : VENTECH
Horizontal Concealed FCU specification table | Vertical coil three pipes system | ||||||||||||
Model FP WA*-3* | 200 | 300 | 400 | 500 | 600 | 700 | 800 | 1000 | 1200 | 1400 | |||
Air volume | H | m3/h | 340 | 510 | 680 | 850 | 1020 | 1200 | 1360 | 1700 | 2040 | 2380 | |
M | 280 | 380 | 515 | 660 | 705 | 910 | 1040 | 1280 | 1560 | 1800 | |||
L | 1B0 | 260 | 340 | 430 | 530 | 610 | 710 | 860 | 1060 | 1190 | |||
Cooling capacity | H | W | 2020 | 3010 | 3700 | 4560 | 5600 | 6400 | 7600 | 9000 | 10800 | 12600 | |
M | 1683 | 2742 | 3000 | 3716 | 4424 | 5630 | 6435 | 7470 | 9296 | 10623 | |||
L | 1561 | 2293 | 2479 | 2921 | 3793 | 4905 | 5606 | 7200 | 8543 | 8820 | |||
Heating capacity | H | W | 3500 | 5300 | 6700 | 8200 | 10100 | 10940 | 13500 | 15000 | 18900 | 20000 | |
M | 2526 | 3533 | 5153 | 5954 | 7099 | 8057 | 9906 | 11560 | 15163 | 18600 | |||
L | 1682 | 2321 | 3449 | 4258 | 4833 | S558 | 6774 | 7500 | 10085 | 14240 | |||
Motor | Input power(H) | Normal ESP (12Pa) | W | 37 | 52 | 62 | 76 | 96 | 113 | 134 | 152 | 189 | 228 |
High ESP (30Pa) | 44 | 69 | 72 | 87 | 108 | 134 | 156 | 174 | 212 | 253 | |||
Super High ESP (50Pa) |
49 | 66 | 84 | 100 | 118 | 158 | 174 | 210 | 250 | 300 | |||
Heat exchanger (3-pipe) | Cooling/ Heating |
Water flow | m3/h | 0.367 | 0.517 | 0.638 | 0 796 | 0.978 | 1.128 | 1.371 | 1.516 | 1 822 | 2.152 |
Water drop pressure | kPa | 17 | 22 | 18 | 20 | 30 | 20 | 30 | 30 | 30 | 40 | ||
Noise | H | Normal ESP (12Pa) | dB(A) | ≤37 | ≤39 | ≤41 | ≤43 | ≤45 | ≤47 | ≤46 | ≤48 | ≤50 | ≤52 |
High ESP (30Pa) | ≤40 | ≤42 | ≤44 | ≤46 | ≤47 | ≤49 | ≤48 | ≤50 | ≤52 | ≤54 | |||
Super High ESP (50Pa) |
≤42 | ≤44 | ≤46 | ≤47 | ≤49 | ≤51 | ≤50 | ≤52 | ≤54 | ≤56 | |||
Dimension | Length | mm | 655 | 785 | 885 | 945 | 1065 | 1185 | 1405 | 1525 | 1725 | 1925 | |
Width | 496 | 466 | 466 | 466 | 466 | 466 | 466 | 466 | 466 | 466 | |||
Height | 243 | 243 | 243 | 243 | 243 | 243 | 243 | 243 | 243 | 243 | |||
Unit weight | No return air box | KG | 12 | 14 | 16 | 17 | 18 | 19 | 26 | 29 | 32 | 35 |
*Cold water cooling condition: return air :DB 27℃/WB 19.5℃; fresh air DB35℃/WB28℃;cold water inlet/outlet 7℃/12℃.
*Heat water cooling condition: return air :DB 15℃/fresh air DB 7℃;inlet/outlet water: 60℃/50℃.
*Heating retur air condition: DB 15℃,fresh air:DB 7 ℃/vapor inlet:115℃,pressure:0.2Mpa.
Programmable thermostats
Setting your smart or programmable thermostat at the right temperature can reduce your cooling costs by about 10 percent. The right temperature varies on your comfort level, but start by setting it at 78° F and experiment until you find the sweet spot. You’ll save about 3 percent on your utility bill for every degree you raise the set temperature for your central air, according to the Department of Energy. And keep in mind that using a box or ceiling fan, which costs little to run, can make you feel 3° F to 4° F cooler.
❤ Want to learn more about Vcare Wholehouse air onditioner,please contact us by email directly. Email:karen@chinaventech.com Tel:0086 13620119598
![]() |
Programmable Thermostat Central Ac Unit Fcu Fan Coil Unit Images |